For push-in terminal blocks, the terminal blocks can be bridged with each other using conductor shafts, the corresponding plug-in bridges can be found in the accessories at the bottom.

Working current: 6.3 A,Operating Voltage: 400 V

Wiring method: Push-in spring connection.

Rated wiring capacity: 4mm2

Installation method: NS 35/7,5,NS 35/15,

 

 


Technical Data

Business Data

Download

Certification

Product Tags

Advantage

The Push-in direct connection technology make the insertion forces reduced by up to 50 percent and tool-free wiring, enable the conductors to be inserted easily and directly.
Made from engineering flame retardants nylon PA66 with brass screw metal.
Made from engineering flame retardants nylon PA66 with brass screw metal.

●The Push-in connection terminal blocks are characterized by easy and tool-free wiring of conductors with ferrules or solid conductors.
●The compact design and front connection enable wiring in a confined space.
●In addition to the testing facility in the double function shaft, all terminal blocks provide an additional test connection.
●With universal foot which can be installed on Din Rail NS 35.
●It can connect two conductors with ease, even large conductor cross sections are not a problem.
●Electric potential distribution can use fixed bridges in the terminal center.
●All types of accessories: End cover, End Stopper, Partition plate, marker trip, fixed bridge, insertion bridge, etc.

Details parameters

Product Description
Product Image    
Product Number UPT-4RD UPTC-4RD/LED24
Product Type Rail wiring terminal  block Rail wiring terminal  block
Mechanical Structure Push-in spring connection Push-in spring connection
Layers 1 1
Electric Potential 1 1
Connection Volume 2 2
Rated Cross Section 4 mm2 4 mm2
Rated Current 6.3A 6.3A
Rated Voltage 400V 24V
Open Side Panel no no
Grounding Feet no no
Other No No
Application Field Widely used in electrical connection, industrial Widely used in electrical connection, industrial
Color (black)、customizable (black)、customizable
Wiring Data
Line Contact
Stripping Length 10mm — 12mm 10mm — 12mm
Rigid Conductor Cross Section 02mm² — 6mm² 0.2mm² — 6mm²
Flexible Conductor Cross Section 0.2mm² — 4mm² 0.2mm² — 4mm²
Rigid Conductor Cross Section AWG 24-10 24-10
Flexible Conductor Cross Section AWG 24-12 24-12
Size
Thickness 6.2mm 8.15mm
Width 55.8mm 67.8mm
High 63.34mm 41.5mm
Material Properties
Flame Retardant Grade, In Line With UL94 V0 V0
Insulation Materials PA PA
Insulation Material Group I I
IEC Electrical Parameters
Standard Test IEC 60947-7-1 IEC 60947-7-1
Rated Voltage(III/3) 400V 24V
Rated Current(III/3) 6.3A 6.3A
Rated Surge Voltage 6kv 6kv
Overvoltage Class III III
Pollution Level 3 3
Electrical Performance Test
Surge Voltage Test Results Passed the test Passed the test
Power Frequency Withstand Voltage Test Results Passed the test Passed the test
Temperature Rise Test Results Passed the test Passed the test
Environmental Conditions
Ambient Temperature (Operating) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)
Ambient Temperature (Storage/Transport) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C)
Ambient Temperature (Assembled) -5 °C — 70 °C -5 °C — 70 °C
Ambient Temperature (Execution) -5 °C — 70 °C -5 °C — 70 °C
Relative Humidity (Storage/Transportation) 30 % — 70 % 30 % — 70 %
Environmental Friendly
RoHS No excessive harmful substances No excessive harmful substances
Standards And Specifications
Connections Are Standard IEC 60947-7-1 IEC 60947-7-1