Products

UPT-1.5/2 Double-level Push-in connection terminal connectors

Short Description:

BrieflyFor power distribution blocks, the terminal blocks can be bridged with each other using conductor shafts, the corresponding plug-in bridges can be found in the accessories at the bottom.

Working current: 15~17.5AOperating Voltage: 300 V

Wiring method: Push-in spring connection.

Rated wiring capacity: 1.5mm2.

Installation method: NS 35/7,5,NS 35/15


Technical Data

Product Tags

Advantage

The Push-in direct connection technology make the insertion forces reduced by up to 50 percent and tool-free wiring, enable the conductors to be inserted easily and directly.
Made from engineering flame retardants nylon PA66 with brass screw metal.

Made from engineering flame retardants nylon PA66 with brass screw metal.

●The Push-in connection terminal blocks are characterized by easy and tool-free wiring of conductors with ferrules or solid conductors.
●The compact design and front connection enable wiring in a confined space.
●In addition to the testing facility in the double function shaft, all terminal blocks provide an additional test connection.
●With universal foot which can be installed on Din Rail NS 35.
●It can connect two conductors with ease, even large conductor cross sections are not a problem.
●Electric potential distribution can use fixed bridges in the terminal center.
●All types of accessories: End cover, End Stopper, Partition plate, marker trip, fixed bridge, insertion bridge, etc.

Details parameters

product description
Product Image
Product number UPT-1.5 UPT-1.5/2 UPT-1.5/2L UPT-1.5/1-2 UPT-1.5/2-2 UPT-1.5/3 UPT-1.5/3L
product type

Rail wiring distribution block

Rail wiring distribution block

Rail wiring distribution block

Rail wiring distribution block

Rail wiring distribution block

Rail wiring distribution block

Rail wiring distribution block

Mechanical structure

Push-in spring connection

Push-in spring connection

Push-in spring connection

Push-in spring connection

Push-in spring connection

Push-in spring connection

Push-in spring connection

layers

1

2

2

1

1

3

3

Electric potential

1

2

1

1

1

3

1

connection volume

2

4

4

3

4

6

6

Rated cross section

1.5mm2

1.5mm2

1.5mm2

1.5mm2

1.5mm2

1.5mm2

1.5mm2

Rated current

17.5A

16A

16A

17.5A

17.5A

15A

15A

Rated voltage

300V

300V

300V

300V

300V

300V

300V

Open side panel

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Grounding feet

no

no

no

no

no

no

no

other

The connecting rail needs to install the rail foot F-NS35

The connecting rail needs to install the rail foot F-NS35

The connecting rail needs to install the rail foot F-NS35

The connecting rail needs to install the rail foot F-NS35

The connecting rail needs to install the rail foot F-NS35

The connecting rail needs to install the rail foot F-NS35

The connecting rail needs to install the rail foot F-NS35

Application field

Widely used in electrical connection, industrial

Widely used in electrical connection, industrial

Widely used in electrical connection, industrial

Widely used in electrical connection, industrial

Widely used in electrical connection, industrial

Widely used in electrical connection, industrial

Widely used in electrical connection, industrial

color

(gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable

(gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable

(gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable

(gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable

(gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable

(gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable

(gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable

Details parameters:
Wiring data
line contact
Stripping length

8mm — 10mm

8mm — 10mm

8mm — 10mm

8mm — 10mm

8mm — 10mm

8mm — 10mm

8mm — 10mm

Rigid Conductor Cross Section

0.2mm² -1.5mm²

0.2mm² -1.5mm²

0.2mm² -1.5mm²

0.2mm² -1.5mm²

0.2mm² -1.5mm²

0.2mm² -1.5mm²

0.2mm² -1.5mm²

Flexible conductor cross section

0.2mm² -1.5mm²

0.2mm² -1.5mm²

0.2mm² -1.5mm²

0.2mm² -1.5mm²

0.2mm² -1.5mm²

0.2mm² -1.5mm²

0.2mm² -1.5mm²

Rigid Conductor Cross Section AWG

26-14

26-14

26-14

26-14

26-14

26-14

26-14

Flexible Conductor Cross Section AWG

26-14

26-14

26-14

26-14

26-14

26-14

26-14

Size (this is the dimension of the UPT-2.5 carrying rail foot F-NS35 installed on the rail)
Thickness

3.5mm

3.5mm

3.5mm

3.5mm

3.5mm

3.5mm

3.5mm

Width

45mm

65.4mm

65.4mm

54mm

63.2mm

97.25mm

97.25mm

Height

30.5mm

41.1mm

41.1mm

30.5mm

30.5mm

51.7mm

51.7mm

NS35/7.5 high

38mm

48.6mm

48.6mm

38mm

38mm

59.2mm

59.2mm

NS35/15 high

53mm

56.1mm

56.1mm

53mm

53mm

66.7mm

66.7mm

NS15/5.5 high

36mm

46.6mm

46.6mm

36mm

36mm

57.2mm

57.2mm

 

Material properties
Flame retardant grade, in line with UL94

V0

V0

V0

V0

V0

V0

V0

Insulation Materials

PA

PA

PA

PA

PA

PA

PA

Insulation material group

I

I

I

I

I

I

I

IEC  IEC Electrical parameters
  standard test

IEC 60947-7-1

IEC 60947-7-1

IEC 60947-7-1

IEC 60947-7-1

IEC 60947-7-1

IEC 60947-7-1

IEC 60947-7-1

Rated voltage(III/3)

300V

300V

300V

300V

300V

300V

300V

Rated current(III/3)

17.5A

16A

16A

17.5A

17.5A

15A

15A

Rated surge voltage

8kv

8kv

8kv

8kv

8kv

6kv

6kv

Overvoltage class

III

III

III

III

III

III

III

pollution level

3

3

3

3

3

3

3

Electrical performance test
Surge Voltage Test Results

Passed the test

Passed the test

Passed the test

Passed the test

Passed the test

Passed the test

Passed the test

Power frequency withstand voltage test results

Passed the test

Passed the test

Passed the test

Passed the test

Passed the test

Passed the test

Passed the test

Temperature rise test results

Passed the test

Passed the test

Passed the test

Passed the test

Passed the test

Passed the test

Passed the test

Environmental conditions
Ambient temperature (operating)

-60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)

-60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)

-60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)

-60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)

-60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)

-60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)

-60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)

Ambient temperature (storage/transport)

-25 °C- 60 °C (short term (up to 24 hours), -60 °C to +70 °C)

-25 °C - 60 °C (short term (up to 24 hours), -60 °C to +70 °C)

-25 °C -60 °C (short term (up to 24 hours), -60 °C to +70 °C)

-25 °C -60 °C (short term (up to 24 hours), -60 °C to +70 °C)

-25 °C-60 °C (short term (up to 24 hours), -60 °C to +70 °C)

-25 °C-60 °C (short term (up to 24 hours), -60 °C to +70 °C)

-25 °C-60 °C (short term (up to 24 hours), -60 °C to +70 °C)

Ambient temperature (assembled)

-5 °C-70 °C

-5 °C -70 °C

-5 °C-70 °C

-5 °C -70 °C

-5 °C-70 °C

-5 °C-70 °C

-5 °C-70 °C

Ambient temperature (execution)

-5 °C-70 °C

-5 °C -70 °C

-5 °C-70 °C

-5 °C -70 °C

-5 °C-70 °C

-5 °C-70 °C

-5 °C-70 °C

Relative Humidity (Storage/Transportation)

30 % — 70 %

30 % — 70 %

30 % — 70 %

30 % — 70 %

30 % — 70 %

30 % — 70 %

30 % — 70 %

Environmental friendly
RoHS

No excessive harmful substances

No excessive harmful substances

No excessive harmful substances

No excessive harmful substances

No excessive harmful substances

No excessive harmful substances

No excessive harmful substances

Standards and Specifications
Connections are standard

IEC 60947-7-1

IEC 60947-7-1

IEC 60947-7-1

IEC 60947-7-1

IEC 60947-7-1

IEC 60947-7-1

IEC 60947-7-1


  • Previous:
  • Next: