Products

JUT10-50/3 feed through high current CU/AL screw terminal blocks din rail distributor connector

Short Description:

Briefly:Modular design, cascading with each other, compact structure Use flame retardant engineering materials, adequate strength and hardness to prevent short circuit and flame retardant design.

 


Technical Data

business data

download

Certification

Product Tags

Advantage

* Save 50%-70% cost comparing to busbar and branch cables
* Provides flexible connection solution with combinations
* Patented design provides reliable and wide area contact
* Low resistance contact points
* Molded with anti-aging, non-flammable, heat & impact resistance material, passed 160A/mm2 short-circuits stress test and UL 94 V-0 flammability test

Details parameters

product description
Product Image
Product number JUT10-50 JUT10-50/2 JUT10-50/3
product type Rail wiring distribution block Rail wiring distribution block Rail wiring distribution block
Mechanical structure Thread type connection Thread type connection Thread type connection
layers 1 1 1
Electric potential 2 4 6
connection volume 2 4 6
Rated cross section 16-50mm2 16-50mm2 16-50mm2
Rated current 160A 160A 160A
Rated voltage 1000V 1000V 1000V
open side panel Yes Yes Yes
grounding feet no no no
other The connecting rail needs to install the rail NS 35/7,5 or NS 35/15 The connecting rail needs to install the rail NS 35/7,5 or NS 35/15 The connecting rail needs to install the rail NS 35/7,5 or NS 35/15
Application field Widely used in electrical connection, industrial Widely used in electrical connection, industrial Widely used in electrical connection, industrial
color (gray)、(dark gray)、(green)、(yellow)、(blue)、customizable (gray)、(dark gray)、(green)、(yellow)、(blue)、customizable (gray)、(dark gray)、(green)、(yellow)、(blue)、customizable
Wiring data
line contact
Stripping length 8mm — 10mm 8mm — 10mm 8mm — 10mm
Rigid Conductor Cross Section 16mm² — 50mm² 16mm² — 50mm² 16mm² — 50mm²
Flexible conductor cross section 16mm² — 50mm² 16mm² — 50mm² 16mm² — 50mm²
Rigid Conductor Cross Section AWG 1/0~6 1/0~6 1/0~6
Flexible Conductor Cross Section AWG 1/0~6 1/0~6 1/0~6
size
thickness 17.7mm 29.8mm 49.6mm
width 51.2mm 49.2mm 51mm
high 45.3mm 45.3mm 43mm
NS35/7.5 high 52.8 mm 52.8mm 50.5mm
NS35/15 high - - -
NS15/5.5 high
Material properties
Flame retardant grade, in line with UL94 V0 V0 V0
Insulation Materials PA PA PA
Insulation material group I I I
IEC Electrical parameters
standard test EN61238-1,EN60947-7-2 EN61238-1,EN60947-7-2 EN61238-1,EN60947-7-2
Rated voltage(III/3) 1000V 1000V 1000V
Rated current(III/3) 160A 160A 160A
Rated surge voltage 8kv 8kv 8kv
Overvoltage class III III III
pollution level 3 3 3
Electrical performance test
Surge Voltage Test Results Passed the test Passed the test Passed the test
Power frequency withstand voltage test results Passed the test Passed the test Passed the test
Temperature rise test results Passed the test Passed the test Passed the test
environmental conditions
Ambient temperature (operating) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)
Ambient temperature (storage/transport) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C)
Ambient temperature (assembled) -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C
Ambient temperature (execution) -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C
Relative Humidity (Storage/Transportation) 30 % — 70 % 30 % — 70 % 30 % — 70 %
Environmental friendly
RoHS No hazardous substances above threshold values No hazardous substances above threshold values No hazardous substances above threshold values
Standards and Specifications
Connections are standard EN61238-1,EN60947-7-2 EN61238-1,EN60947-7-2 EN61238-1,EN60947-7-2

  • Previous: