Products

JUT1-2.5 series (Din rail types fuse terminal block JUK 2.5mm plastic screw Terminal Block With Led Indicator)

Short Description:

The screw-type industrial terminal block has strong static connection stability, high versatility, and can be quickly installed on U-shaped guide rails and G-shaped guide rails. Abundant and practical accessories. Traditional and reliable.

Working current: 24 A, Operating Voltage: 800V.

Wiring method: screw connection.

Rated wiring capacity: 2.5 mm2

Installation method: NS 35/7.5, NS 35/15, NS32.


Technical Data

Product Tags

JUT1-2.5 Series Advantages

Universal mounting foot, available for rails NS35 and NS32.

Static connection stability is strong.

Potential distribution with bridges.

JUT1-2.5 Series

Product number JUT1-2.5 JUT1-2.5B JUT1-2.5PE JUT1-2.5BPE JUT1-2.5/2 JUT1-2.5/2L JUT1-2.5/2Q JUT1-2.5E JUT1-2.5E/PE JUT1-2.5S
Product type Rail Terminals Rail Terminals Rail ground terminal Rail ground terminal Rail ground terminal Rail ground terminal Rail ground terminal Rail ground terminal Rail ground terminal Rail ground terminal
Mechanical structure screw type screw type screw type screw type screw type screw type screw type screw type screw type screw type
Layers 1 1 1 1 2 2 2 1 1 1
Electric Potential 1 1 1 1 2 1 2 1 1 1
Connection volume 2 2 2 2 4 4 4 2 2 2
Rated cross section 2.5 mm2 2.5 mm2 2.5 mm2 2.5 mm2 2.5 mm2 2.5 mm2 2.5 mm2 2.5 mm2 2.5 mm2 2.5 mm2
Rated current 24A 24A 24A 24A 24A 24A 57A
Rated voltage 800V 690V 500V 500V 500V 500V 500V
Open side panel yes yes no no yes yes yes yes no yes
Grounding feet no no yes yes no no no no yes no
Other When aligned with terminals of the same size, an end plate must be inserted to isolate voltages greater than 690 V. Bridgeable up and down
Application field Widely used in electrical connection, industrial
Color gray, customizable gray, customizable yellow and green yellow and green gray, customizable gray, customizable gray, customizable gray, customizable yellow and green gray, customizable

Wiring Data

Line contact
Stripping length 8mm 8mm 8mm 7mm 8mm 8mm 8mm 8mm 8mm 12mm
Rigid Conductor Cross Section 0.2mm² — 4mm² 0.2mm² — 4mm² 0.2mm² — 4mm² 0.2mm² — 4mm² 0.2mm² — 4mm² 0.2mm² — 4mm² 0.2mm² — 4mm² 0.2mm² — 4mm² 0.2mm² — 4mm² 0.2mm² — 4mm²
Flexible conductor cross section 0.2mm² — 2.5mm² 0.2mm² — 2.5mm² 0.2mm² — 2.5mm² 0.2mm² — 4mm² 0.2mm² — 2.5mm² 0.2mm² — 2.5mm² 0.2mm² — 2.5mm² 0.2mm² — 2.5mm² 0.2mm² — 2.5mm² 0.2mm² — 2.5mm²
Rigid Conductor Cross Section AWG 24-12 24-12 24-12 24-12 24-12 24-12 24-12 24-12 24-12 24-12
Flexible Conductor Cross Section AWG 24-14 24-14 24-14 24-14 24-14 24-14 24-14 24-14 24-14 24-14

Size

Thickness 5.2mm 6.2mm 5.2mm 6.2mm 5.2mm 5.2mm 5.2mm 5.2mm 5.2mm 8.2mm
Width 42.5mm 42.5mm 42.5mm 42.5mm 56mm 56mm 67mm 28mm 28mm 61mm
high 57.5mm
NS35/7.5 high 47mm 42mm 47mm 42mm 62mm 62mm 62mm 58.5mm
NS35/15 high 54.5mm 49.5mm 54.5mm 49.5mm 69.5mm 69.5mm 69.5mm 66mm
NS15/5.5 high 32mm 32mm

Material Properties

Flame retardant grade, in line with UL94 V0 V0 V0 V0 V0 V0 V0 V2 V0 V0
Insulation Materials PA PA PA PA PA PA PA PA PA PA
Insulation material group I I I I I I I I I I

IEC Electrical Parameters

Standard test IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-2 IEC 60947-7-2 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-2 IEC 60947-7-1
Rated voltage(III/3) 800V 690V 500V 500V 500V 500V
Rated current(III/3) 24A 24A 24A 24A 24A 24A
Rated surge voltage 8kv 8kv 8kv 6kv 6kv 6kv 6kv 6kv 6kv 6kv
Overvoltage class III III III III III III III III III III
Pollution level 3 3 3 3 3 3 3 3 3 3

Electrical Performance Test

Surge Voltage Test Results Passed the test Passed the test Passed the test Passed the test Passed the test Passed the test Passed the test Passed the test Passed the test Passed the test
Power frequency withstand voltage test results Passed the test Passed the test Passed the test Passed the test Passed the test Passed the test Passed the test Passed the test Passed the test Passed the test
Temperature rise test results Passed the test Passed the test Passed the test Passed the test Passed the test Passed the test Passed the test Passed the test Passed the test Passed the test

Environmental Conditions

Surge Voltage Test Results -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -40 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -40 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -40 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -40 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)
Ambient temperature (storage/transport) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -5 °C — 70 °C (short term (up to 24 hours), -60 °C to +70 °C) -5 °C — 70 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -5 °C — 70 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -5 °C — 70 °C (short term (up to 24 hours), -60 °C to +70 °C)
Ambient temperature (assembled) -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C
Ambient temperature (execution) -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C
Relative Humidity (Storage/Transportation) 30 % — 70 % 30 % — 70 % 25 % — 75 % 25 % — 75 % 30 % — 70 % 30 % — 70 % 25 % — 75 % 30 % — 70 % 30 % — 70 % 25 % — 75 %

Environmental Friendly

RoHS No excessive harmful substances No excessive harmful substances No excessive harmful substances No excessive harmful substances No excessive harmful substances No excessive harmful substances No excessive harmful substances No excessive harmful substances No excessive harmful substances No excessive harmful substances

Standards and Specifications

Connections are standard IEC 60947-7-1 IEC 60947-7-2 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-2 IEC 60947-7-1