Products

JUT1-4/1-2 Din Rail Screw Type Wire Connector Terminal

Short Description:

The screw-type industrial terminal block has strong static connection stability, high versatility, and can be quickly installed on U-shaped guide rails and G-shaped guide rails. Abundant and practical accessories. Traditional and reliable.

Working current: 32 AOperating Voltage500V

AWG:24-12

Wiring method: screw connection.

Rated wiring capacity: 4mm2

Installation method: NS 35/7.5NS 35/15, NS32.


Technical Data

Product Tags

Advantage:

  •  Save 50%-70% cost comparing to busbar and branch cables
  •  Provides flexible connection solution with combinations
  •  Patented design provides reliable and wide area contact
  •  Low resistance contact points
  •  Molded with anti-aging, non-flammable, heat & impact resistance material, passed 160A/mm2 short-circuits stress test and UL 94 V-0 flammability test

Accessories of a product

Model  Number JUT1-4/1-2
End Plate G-GUT1-4/1-2
Central adaptor JFB2-4

JFB3-4

JFB10-4

Side adaptor JEB2-4

JEB3-4

JEB10-4

Insulating spacer JS-K
Marker bar ZB6

JUT1-4/1-2 Description

Product Number JUT1-4/1-2
Product Type One-in-two-out rail terminal block
Mechanical Structure screw type
Layers 1
Electric Potential 1
Connection Volume 3
Rated Cross Section 4mm2
Rated Current 32A
Rated Voltage 500V
Open Side Panel no
Grounding Feet no
Other Multi-conductor
Application Field Widely used in electrical connection, industrial
Color Gray/ Customizable

Wiring Data

Stripping Length 8mm
Rigid Conductor Cross Section 0.2mm² — 4mm²
Flexible Conductor Cross Section 0.2mm² — 4mm²
Rigid Conductor Cross Section AWG 12-24
Flexible Conductor Cross Section AWG 12-24

Size

Thickness 6.2mm
Width 50.5mm
High 47mm
NS35/7.5 High 54.5mm

Material Properties

Flame Retardant Grade, In Line With UL94 V2
Insulation Materials
Insulation Material Group I

IEC Electrical Parameters

Standard Test IEC 60947-7-1
Rated Voltage(III/3) 500V
Rated Current(III/3) 32A
Rated Surge Voltage 6kv
Overvoltage Class
Pollution Level 3

Electrical Performance Test

Surge Voltage Test Results Passed the test
Power Frequency Withstand Voltage Test Results Passed the test
Temperature Rise Test Results Passed the test

Environmental Conditions

Surge Voltage Test Results -60 °C – 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)
Ambient Temperature (Storage/Transport) -25 °C – 60 °C (short term (up to 24 hours), -60 °C to +70 °C)
Ambient Temperature (Assembled) -5 °C — 70 °C
Ambient Temperature (Execution) -5 °C — 70 °C
Relative Humidity (Storage/Transportation) 30 % — 70 %

Environmental Friendly

RoHS No excessive harmful substances
Connections Are Standard IEC 60947-7-1

 

 


  • Previous: