Products

JUT15-12X2.5-P series (in-line link, power distribution block, terminal block, power distribution box)

Short Description:

For power distribution blocks, the terminal blocks can be bridged with each other using conductor shafts, the corresponding plug-in bridges can be found in the accessories at the bottom.

Working current: 24 A,Operating Voltage: 690 V.

Wiring method: Push-in spring connection.

Rated wiring capacity:2.5mm².

Installation method: NS 35/7.5,NS 35/15.


Technical Data

Business Data

Download

Certification

Product Tags

Advantage

Can be installed vertically or parallel to DIN rail, saving up to 50% of rail space
It can be installed by DIN rail, direct installation or adhesive installation, which is more flexible to use
Time-saving wire connection thanks to tool-free push-in connection technology
Modules can be installed immediately without manual bridging, saving up to 80% of time
Different colors, the wiring is more clear.

Details parameters

product description
Product Image
Product number JUT15-4x2.5-P JUT15-6x2.5-P JUT15-10x2.5-P JUT15-12x2.5-P JUT15-18x2.5-P
product type Rail wiring distribution block Rail wiring distribution block Rail wiring distribution block Rail wiring distribution block Rail wiring distribution block
Mechanical structure Push-in spring connection Push-in spring connection Push-in spring connection Push-in spring connection Push-in spring connection
layers 1 1 1 1 1
Electric potential 1 1 1 1 1
connection volume 4 6 10 12 18
Rated cross section 2.5 mm2 2.5 mm2 2.5mm2 2.5mm2 2.5mm2
Rated current 24A 24A 24A 24A 24A
Rated voltage 690V 690V 690V 690V 690V
open side panel no no no no no
grounding feet no no no no no
other The connecting rail needs to install the rail seat PAD-NS15/35 The connecting rail needs to install the rail seat PAD-NS15/35 The connecting rail needs to install the rail seat PAD-NS15/35 The connecting rail needs to install the rail seat PAD-NS15/35 The connecting rail needs to install the rail seat PAD-NS15/35
Application field Widely used in electrical connection, industrial Widely used in electrical connection, industrial Widely used in electrical connection, industrial Widely used in electrical connection, industrial Widely used in electrical connection, industrial
color graydark graygreenyellowcreamorangeblackredbluewhitepurpleBrowncustomizable graydark graygreenyellowcreamorangeblackredbluewhitepurpleBrowncustomizable gray、dark gray、green、yellow、cream、orange、black、red、blue、white、purple、Brown、customizable gray、dark gray、green、yellow、cream、orange、black、red、blue、white、purple、Brown、customizable gray、dark gray、green、yellow、cream、orange、black、red、blue、white、purple、Brown、customizable
Wiring data
line contact
Stripping length 8mm  10mm 8mm  10mm 8mm  10mm 8mm  10mm 8mm  10mm
Rigid Conductor Cross Section 0.14mm²  4mm² 0.14mm²  4mm² 0.14mm²  4mm² 0.14mm²  4mm² 0.14mm²  4mm²
Flexible conductor cross section 0.14mm²  2.5mm² 0.14mm²  2.5mm² 0.14mm²  2.5mm² 0.14mm²  2.5mm² 0.14mm²  2.5mm²
Rigid Conductor Cross Section AWG 26-12 26-12 26-12 26-12 26-12
Flexible Conductor Cross Section AWG 26-14 26-14 26-14 26-14 26-14
size(This is the size of the JUT15P carrying rail holder PAD-NS15/35 installed on the rail)
thickness 28.8mm 28.8mm 28.8mm 28.8mm 28.8mm
width 58.5mm 58.5mm 58.5mm 58.5mm 58.5mm
high 21.7mm 21.7mm 21.7mm 21.7mm 21.7mm
NS35/7.5 high 32.5mm 32.5mm 32.5mm 32.5mm 32.5mm
NS35/15 high 40mm 40mm 40mm 40mm 40mm
NS15/5.5 high 30.5mm 30.5mm 30.5mm 30.5mm 30.5mm
Material properties
Flame retardant grade, in line with UL94 V0 V0 V0 V0 V0
Insulation Materials PA PA PA PA PA
Insulation material group I I I I I
IEC电气参数  IEC Electrical parameters
测试标准  standard test IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1
Rated voltageIII/3 690V 690V 690V 690V 690V
Rated currentIII/3 24A 24A 24A 24A 24A
Rated surge voltage 8kv 8kv 8kv 8kv 8kv
Overvoltage class III III III III III
pollution level 3 3 3 3 3
Electrical performance test
Surge Voltage Test Results Passed the test Passed the test Passed the test Passed the test Passed the test
Power frequency withstand voltage test results Passed the test Passed the test Passed the test Passed the test Passed the test
Temperature rise test results Passed the test Passed the test Passed the test Passed the test Passed the test
environmental conditions
Ambient temperature (operating) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)
Ambient temperature (storage/transport) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C)
Ambient temperature (assembled) -5 °C  70 °C -5 °C  70 °C -5 °C  70 °C -5 °C  70 °C -5 °C  70 °C
Ambient temperature (execution) -5 °C  70 °C -5 °C  70 °C -5 °C  70 °C -5 °C  70 °C -5 °C  70 °C
Relative Humidity (Storage/Transportation) 30 %  70 % 30 %  70 % 30 %  70 % 30 %  70 % 30 %  70 %
Environmental friendly
RoHS No excessive harmful substances No excessive harmful substances No excessive harmful substances No excessive harmful substances No excessive harmful substances
Standards and Specifications
Connections are standard IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1

  • Previous: