Can be installed vertically or parallel to DIN rail, saving up to 50% of rail space.
It can be installed by DIN rail, direct installation or adhesive installation, which is more flexible to use.
Time-saving wire connection thanks to tool-free push-in connection technology.
Modules can be installed immediately without manual bridging, saving up to 80% of time.
Different colors, the wiring is more clear.
Product number | JUT15-6-4x2.5-P | JUT15-6-6x2.5-P | JUT15-6-10x2.5-P | JUT15-6-12x2.5-P | JUT15-6-18x2.5-P |
product type | Din rail distribution terminal block | Din rail distribution terminal block | Din rail distribution terminal block | Din rail distribution terminal block | Din rail distribution terminal block |
Mechanical structure | Push-in spring connection | Push-in spring connection | Push-in spring connection | Push-in spring connection | Push-in spring connection |
layers | 1 | 1 | 1 | 1 | 1 |
Electric Potential | 1 | 1 | 1 | 1 | 1 |
connection volume | 5 | 7 | 11 | 13 | 19 |
Rated cross section | 2.5 mm2 | 2.5 mm2 | 2.5mm2 | 2.5mm2 | 2.5mm2 |
Rated current | 24A | 24A | 24A | 24A | 24A |
Rated voltage | 690V | 690V | 690V | 690V | 690V |
open side panel | no | no | no | no | no |
grounding feet | no | no | no | no | no |
other | The connecting rail needs to install the rail seat PAD-NS15/35 | The connecting rail needs to install the rail seat PAD-NS15/35 | The connecting rail needs to install the rail seat PAD-NS15/35 | The connecting rail needs to install the rail seat PAD-NS15/35 | The connecting rail needs to install the rail seat PAD-NS15/35 |
Application field | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial |
color | gray、dark gray、green、yellow、cream、orange、black、red、blue、white、purple、Brown、customizable | gray、dark gray、green、yellow、cream、orange、black、red、blue、white、purple、Brown、customizable | gray、dark gray、green、yellow、cream、orange、black、red、blue、white、purple、Brown、customizable | gray、dark gray、green、yellow、cream、orange、black、red、blue、white、purple、Brown、customizable | gray、dark gray、green、yellow、cream、orange、black、red、blue、white、purple、Brown、customizable |
Wire contact | |||||
Stripping length | 8mm —10mm | 8mm —10mm | 8mm —10mm | 8mm —10mm | 8mm —10mm |
Rigid Conductor Cross Section | 0.14mm² — 4mm² | 0.14mm² — 4mm² | 0.14mm² — 4mm² | 0.14mm² — 4mm² | 0.14mm² — 4mm² |
Flexible conductor cross section | 0.14mm² — 2.5mm² | 0.14mm² — 2.5mm² | 0.14mm² — 2.5mm² | 0.14mm² — 2.5mm² | 0.14mm² — 2.5mm² |
Rigid Conductor Cross Section AWG | 26-12 | 26-12 | 26-12 | 26-12 | 26-12 |
Flexible Conductor Cross Section AWG | 26-14 | 26-14 | 26-14 | 26-14 | 26-14 |
line contact | |||||
Stripping length | 10mm —12mm | 10mm —12mm | 10mm —12mm | 10mm —12mm | 10mm —12mm |
Rigid Conductor Cross Section | 0.2mm² — 4mm² | 0.2mm² — 4mm² | 0.2mm² — 4mm² | 0.2mm² — 4mm² | 0.2mm² — 4mm² |
Flexible conductor cross section | 0.2mm² — 2.5mm² | 0.2mm² — 2.5mm² | 0.2mm² — 2.5mm² | 0.2mm² — 2.5mm² | 0.2mm² — 2.5mm² |
Rigid Conductor Cross Section AWG | 20-8 | 20-8 | 20-8 | 20-8 | 20-8 |
Flexible Conductor Cross Section AWG | 20-10 | 20-10 | 20-10 | 20-10 | 20-10 |
thickness | 28.8mm | 28.8mm | 28.8mm | 28.8mm | 28.8mm |
width | 58.5mm | 58.5mm | 58.5mm | 58.5mm | 61.3mm |
high | 21.7mm | 21.7mm | 21.7mm | 21.7mm | 21.7mm |
NS35/7.5 high | 32.5mm | 32.5mm | 32.5mm | 32.5mm | 32.5mm |
NS35/15 high | 40mm | 40mm | 40mm | 40mm | 40mm |
NS15/5.5 high | 30.5mm | 30.5mm | 30.5mm | 30.5mm | 30.5mm |
Flame retardant grade, comply with UL94 | V0 | V0 | V0 | V0 | V0 |
Insulation Materials | PA | PA | PA | PA | PA |
Insulation material group | I | I | I | I | I |
standard test | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 |
Rated voltage(III/3) | 690V | 690V | 690V | 690V | 690V |
Rated current(III/3) | 24A | 24A | 24A | 24A | 24A |
Rated surge voltage | 8kv | 8kv | 8kv | 8kv | 8kv |
Overvoltage class | III | III | III | III | III |
pollution level | 3 | 3 | 3 | 3 | 3 |
Surge Voltage Test Results | Passed the test | Passed the test | Passed the test | Passed the test | Passed the test |
Power frequency withstand voltage test results | Passed the test | Passed the test | Passed the test | Passed the test | Passed the test |
Temperature rise test results | Passed the test | Passed the test | Passed the test | Passed the test | Passed the test |
Ambient temperature (operating) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics relative temperature) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics relative temperature) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics relative temperature) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics relative temperature) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics relative temperature) |
Ambient temperature (storage/transport) | -25 °C — 60 °C short term (up to 24 hours), -60 °C to +70 °C | -25 °C — 60 °C short term (up to 24 hours), -60 °C to +70 °C | -25 °C — 60 °C short term (up to 24 hours), -60 °C to +70 °C | -25 °C — 60 °C short term (up to 24 hours), -60 °C to +70 °C | -25 °C — 60 °C short term (up to 24 hours), -60 °C to +70 °C |
Ambient temperature (assembled) | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C |
Ambient temperature (execution) | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C |
Relative Humidity (Storage/Transportation) | 30 % — 70 % | 30 % — 70 % | 30 % — 70 % | 30 % — 70 % | 30 % — 70 % |
RoHS | No excessive harmful substances | No excessive harmful substances | No excessive harmful substances | No excessive harmful substances | No excessive harmful substances |
Connections are standard | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 |