Products

JUT15-6-6X2.5(Through Hole Terminal Block cable wire din rail connectors )

Short Description:

For power distribution blocks, the terminal blocks can be bridged with each other using conductor shafts.

Working current: 24 A, Operating Voltage: 690 V.

Wiring method: Push-in spring connection.

Rated wiring capacity: 2.5mm2.

Installation method: NS 35/7.5, NS 35/15.


Technical Data

Business Data

Download

Certification

Product Tags

Advantages of JUT15-6-2.5 Series

Can be installed vertically or parallel to DIN rail, saving up to 50% of rail space.

It can be installed by DIN rail, direct installation or adhesive installation, which is more flexible to use.

Time-saving wire connection thanks to tool-free push-in connection technology.

Modules can be installed immediately without manual bridging, saving up to 80% of time.

Different colors, the wiring is more clear.

JUT15-6-2.5 Series

Product number JUT15-6-4x2.5-F JUT15-6-6x2.5-F JUT15-6-10x2.5-F JUT15-6-12x2.5-F JUT15-6-18x2.5-F
product type Plug-in terminal block Plug-in terminal block Plug-in terminal block Plug-in terminal block Plug-in terminal block
Mechanical structure Push-in spring connection Push-in spring connection Push-in spring connection Push-in spring connection Push-in spring connection
layers 1 1 1 1 1
Electric Potential 1 1 1 1 1
connection volume 5 7 11 13 19
Rated cross section 2.5 mm2 2.5 mm2 2.5mm2 2.5mm2 2.5mm2
Rated current 24A 24A 24A 24A 24A
Rated voltage 690V 690V 690V 690V 690V
open side panel no no no no no
grounding feet no no no no no
other The connecting rail needs to install the rail foot F-NS35
Application field It is generally used for related supporting facilities such as electric connection industries and industries.
color Gray, dark gray, green, yellow, cream, orange, black, red, blue, white, purple, brown, customisable

Wiring Data

load contact
Stripping length 8mm —10mm 8mm —10mm 8mm —10mm 8mm —10mm 8mm —10mm
Rigid Conductor Cross Section 0.14mm² — 4mm² 0.14mm² — 4mm² 0.14mm² — 4mm² 0.14mm² — 4mm² 0.14mm² — 4mm²
Flexible conductor cross section 0.14mm² — 2.5mm² 0.14mm² — 2.5mm² 0.14mm² — 2.5mm² 0.14mm² — 2.5mm² 0.14mm² — 2.5mm²
Rigid Conductor Cross Section AWG 26-12 26-12 26-12 26-12 26-12
Flexible Conductor Cross Section AWG 26-14 26-14 26-14 26-14 26-14
line contact
Stripping length 10mm —12mm 10mm —12mm 10mm —12mm 10mm —12mm 10mm —12mm
Rigid Conductor Cross Section 0.5mm² — 10mm² 0.5mm² — 10mm² 0.5mm² — 10mm² 0.5mm² — 10mm² 0.5mm² — 10mm²
Flexible conductor cross section 0.5mm² — 10mm² 0.5mm² — 10mm² 0.5mm² — 10mm² 0.5mm² — 10mm² 0.5mm² — 10mm²
Rigid Conductor Cross Section AWG 20-8 20-8 20-8 20-8 20-8
Flexible Conductor Cross Section AWG 20-10 20-10 20-10 20-10 20-10

Size (this is the dimension of the JUT15F carrying rail foot F-NS35 installed on the rail)

thickness 24mm 29.2mm 39.6mm 44.8mm 60.4mm
width 45.5mm 45.5mm 45.5mm 45.5mm 45.5mm
Height 21.7mm 21.7mm 21.7mm 21.7mm 21.7mm
NS35/7.5 high 31.1mm 31.1mm 31.1mm 31.1mm 31.1mm
NS35/15 high 38.6mm 38.6mm 38.6mm 38.6mm 38.6mm
NS15/5.5 high

Material Properties

Flame retardant grade, in line with UL94 V0 V0 V0 V0 V0
Insulation Materials PA PA PA PA PA
Insulation material group I I I I I

IEC Electrical Parameters

standard test IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1
Rated voltage(III/3) 690V 690V 690V 690V 690V
Rated current(III/3) 24A 24A 24A 24A 24A
Rated surge voltage 8kv 8kv 8kv 8kv 8kv
Overvoltage class III III III III III
pollution level 3 3 3 3 3

Electrical Performance Test

Surge Voltage Test Results Passed the test Passed the test Passed the test Passed the test Passed the test
Power frequency withstand voltage test results Passed the test Passed the test Passed the test Passed the test Passed the test
Temperature rise test results Passed the test Passed the test Passed the test Passed the test Passed the test

Environmental Conditions

Ambient temperature (operating) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)
Ambient temperature (storage/transport) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C)
Ambient temperature (assembled) -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C
Ambient temperature (execution) -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C
Relative Humidity (Storage/Transportation) 30 % — 70 % 30 % — 70 % 30 % — 70 % 30 % — 70 % 30 % — 70 %

Environmental Friendly

RoHS No excessive harmful substances

Standards and Specifications

Connections are standard IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1

JUT15-6-6x2.5-F

JUT15-6-6x2-(2)
JUT15-6-6x2-(3)
JUT15-6-6x2-(1)

JUT15-6-10x2.5-F

JUT15-6-10x2-(3)
JUT15-6-10x2-(1)
JUT15-6-10x2-(2)

JUT15-6-12x2.5-F

JUT15-6-12x2-(1)
JUT15-6-12x2-(2)
JUT15-6-12x2-(3)

JUT15-6-18x2.5-F

JUT15-6-18x2-(2)
JUT15-6-18x2-(3)
JUT15-6-18x2-(1)

  • Previous:
  • Next: