Products

UPT-4/2-2 Lead through Plug In Panel Mount Spring Terminal Block Connector

Short Description:

BrieflyFor power distribution blocks, the terminal blocks can be bridged with each other using conductor shafts, the corresponding plug-in bridges can be found in the accessories at the bottom.

Wiring method: Push-in spring connection.

Rated wiring capacity: 2.5mm2.

Installation method: NS 35/7,5,NS 35/15


Technical Data

Product Tags

Advantage

The Push-in direct connection technology make the insertion forces reduced by up to 50 percent and tool-free wiring, enable the conductors to be inserted easily and directly.
Made from engineering flame retardants nylon PA66 with brass screw metal.
Made from engineering flame retardants nylon PA66 with brass screw metal.
●The Push-in connection terminal blocks are characterized by easy and tool-free wiring of conductors with ferrules or solid conductors.
●The compact design and front connection enable wiring in a confined space.
●In addition to the testing facility in the double function shaft, all terminal blocks provide an additional test connection.
●With universal foot which can be installed on Din Rail NS 35.
●It can connect two conductors with ease, even large conductor cross sections are not a problem.
●Electric potential distribution can use fixed bridges in the terminal center.
●All types of accessories: End cover, End Stopper, Partition plate, marker trip, fixed bridge, insertion bridge, etc.

Details parameters

product description
Product Image          
Product number UPT-4 UPT-4/1-2 UPT-4/2 UPT-4/2L UPT-4/2-2
product type Rail wiring distribution block Rail wiring distribution block Rail wiring distribution block Rail wiring distribution block Rail wiring distribution block
Mechanical structure Push-in spring connection Push-in spring connection Push-in spring connection Push-in spring connection Push-in spring connection
layers 1 1 2 1 1
Electric potential 1 1 1 1 1
connection volume 2 3 4 4 4
Rated cross section 4 mm2 4 mm2 4 mm2 4 mm2 4 mm2
Rated current 32A 32A 28A 30A 32A
Rated voltage 800V 800V 500V 500V 800V
open side panel Yes Yes Yes Yes Yes
grounding feet no no no no no
other The connecting rail needs to install the rail foot F-NS35 The connecting rail needs to install the rail foot F-NS35 The connecting rail needs to install the rail foot F-NS35 The connecting rail needs to install the rail foot F-NS35 The connecting rail needs to install the rail foot F-NS35
Application field Widely used in electrical connection, industrial Widely used in electrical connection, industrial Widely used in electrical connection, industrial Widely used in electrical connection, industrial Widely used in electrical connection, industrial
color (gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable (gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable (gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable (gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable (gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable
Wiring data
line contact
Stripping length 8mm — 10mm 8mm — 10mm 8mm — 10mm 8mm — 10mm  
Rigid Conductor Cross Section 0.2mm² — 6mm² 0.2mm² — 6mm² 0.2mm² — 6mm² 0.2mm² — 6mm² 0.2mm² — 6mm²
Flexible conductor cross section 0.2mm² — 6mm² 0.2mm² — 6mm² 0.2mm² — 6mm² 0.2mm² — 6mm² 0.2mm² — 6mm²
Rigid Conductor Cross Section AWG 24-10 24-10 24-10 24-10 24-10
Flexible Conductor Cross Section AWG 24-10 24-10 24-10 24-10 24-10
size (this is the dimension of the UPT-4 carrying rail foot F-NS35 installed on the rail)
thickness 6.2mm 6.2mm 6.2mm 6.2mm 6.2mm
width 55.8mm 66.4mm 83.7mm 83.7mm 76.9mm
high 35.3mm 35.3mm 45.9mm 45.9mm 35.3mm
NS35/7.5 high 36.8 mm 36.8mm 47.4mm 47.4mm 36.8mm
NS35/15 high          
NS15/5.5 high          
Material properties
Flame retardant grade, in line with UL94 V0 V0 V0 V0 V0
Insulation Materials PA PA PA PA PA
Insulation material group I I I I I
IEC  IEC Electrical parameters
  standard test IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1
Rated voltage(III/3) 800V 800V 500V 500V 800V
Rated current(III/3) 32A 32A 28A 30A 32A
Rated surge voltage 8kv 8kv 8kv 6kv 8kv
Overvoltage class III III III III III
pollution level 3 3 3 3 3
Electrical performance test
Surge Voltage Test Results Passed the test Passed the test Passed the test Passed the test Passed the test
Power frequency withstand voltage test results Passed the test Passed the test Passed the test Passed the test Passed the test
Temperature rise test results Passed the test Passed the test Passed the test Passed the test Passed the test
environmental conditions
Ambient temperature (operating) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)
Ambient temperature (storage/transport) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C)  -25 °C - 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)  -25 °C - 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembled) -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C
Ambient temperature (execution) -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C
Relative Humidity (Storage/Transportation) 30 % — 70 % 30 % — 70 % 30 % — 70 % 30 % ... 70 % 30 % ... 70 %
Environmental friendly
RoHS No excessive harmful substances No excessive harmful substances No excessive harmful substances No hazardous substances above threshold values No hazardous substances above threshold values
Standards and Specifications
Connections are standard IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1