Products

JUT14-6/1-2 one-in-two-out power distribution push-in din rail connector

Short Description:

Briefly:For power distribution blocks, the terminal blocks can be bridged with each other using conductor shafts, the corresponding plug-in bridges can be found in the accessories at the bottom.

Working current: 40A,Operating Voltage: 800 V

Wiring method: Push-in spring connection.

Rated wiring capacity: 6mm2.

Installation method: NS 35/7,5,NS 35/15,


Technical Data

business data

download

Certification

Product Tags

Advantage

The Push-in direct connection technology make the insertion forces reduced by up to 50 percent and tool-free wiring, enable the conductors to be inserted easily and directly.
Made from engineering flame retardants nylon PA66 with brass screw metal.

●The Push-in connection terminal blocks are characterized by easy and tool-free wiring of conductors with ferrules or solid conductors.
●The compact design and front connection enable wiring in a confined space.
●In addition to the testing facility in the double function shaft, all terminal blocks provide an additional test connection.
●With universal foot which can be installed on Din Rail NS 35.
●It can connect two conductors with ease, even large conductor cross sections are not a problem.
●Electric potential distribution can use fixed bridges in the terminal center.
●All types of accessories: End cover, End Stopper, Partition plate, marker trip, fixed bridge, insertion bridge, etc.

Details parameters

Details parameters:

Product Image

Product number

JUT14-6/DK/GY

JUT14-6/1-2/DK/GY

JUT14-6 PE

JUT14-6/1-2 PE

product type

Rail wiring distribution block

Rail wiring distribution block

Rail wiring distribution block

Rail wiring distribution block

Mechanical structure

Push-in spring connection

Push-in spring connection

Push-in spring connection

Push-in spring connection

layers

1

1

1

1

Electric potential

1

1

1

1

connection volume

2

3

2

3

Rated cross section

6 mm2

6 mm2

6 mm2

6 mm2

Rated current

40A

40A

40A

40A

Rated voltage

800V

800V

800V

800V

open side panel

Yes

Yes

no

no

grounding feet

no

no

Yes

Yes

other

The connecting rail needs to install the rail foot F-NS35

The connecting rail needs to install the rail foot F-NS35

The connecting rail needs to install the rail NS 35/7,5 or NS 35/15

The connecting rail needs to install the rail NS 35/7,5 or NS 35/15

Application field

Widely used in electrical connection, industrial

Widely used in electrical connection, industrial

Widely used in electrical connection, industrial

Widely used in electrical connection, industrial

color

(gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable

(gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、白色(white)、(purple)、(Brown)、customizable

Green and Yellow

Green and Yellow

       

Stripping length

14mm

14mm

14mm

14mm

Rigid Conductor Cross Section

0.5-10mm²

0.5-10mm²

0.5-10mm²

0.5-10mm²

Flexible conductor cross section

0.5-6mm²

0.5-6mm²

0.5-6mm²

0.5-6mm²

Rigid Conductor Cross Section AWG

24-8

0.5-6mm²

0.5-6mm²

24-8

Flexible Conductor Cross Section AWG

24-10

24-10

24-10

24-10

       

size (this is the dimension of the JUT14-6 carrying rail foot F-NS35 installed on the rail)

thickness

8.2mm

8.2mm

8.2mm

8.2mm

width

61.2mm

78mm

61.2mm

78mm

high

41.2mm

41.7mm

41.2mm

41.7mm

NS35/7.5 high

48.7mm

49.2mm

48.7mm

49.2mm

NS35/15 high

56.2mm

56.7mm

56.2mm

56.7mm

NS15/5.5 high

       

Material properties

Flame retardant grade, in line with UL94

V0

V0

V0

V0

Insulation Materials

PA

PA

PA

PA

Insulation material group

I

I

I

I

       

IEC Electrical parameters

standard test

IEC 60947-7-1

IEC 60947-7-1

IEC 60947-7-1

IEC 60947-7-1

Rated voltage(III/3)

800V

800V

800V

800V

Rated current(III/3)

40A

40A

40A

40A

Rated surge voltage

6kv

6kv

6kv

6kv

Overvoltage class

III

III

III

III

pollution level

3

3

3

3

       

Electrical performance test

Surge Voltage Test Results

Passed the test

Passed the test

Passed the test

Passed the test

Power frequency withstand voltage test results

Passed the test

Passed the test

Passed the test

Passed the test

Temperature rise test results

Passed the test

Passed the test

Passed the test

Passed the test

       

environmental conditions

Ambient temperature (operating)

-60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)

-60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)

-40℃~+105℃(Depends on the derating curve)

-40℃~+105℃(Depends on the derating curve)

Ambient temperature (storage/transport)

-25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C)

-25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C)

 -25 °C - 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)

 -25 °C - 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)

Ambient temperature (assembled)

-5 °C — 70 °C

-5 °C — 70 °C

-5 °C — 70 °C

-5 °C — 70 °C

Ambient temperature (execution)

-5 °C — 70 °C

-5 °C — 70 °C

-5 °C — 70 °C

-5 °C — 70 °C

Relative Humidity (Storage/Transportation)

30 % — 70 %

30 % — 70 %

30 % — 70 %

30 % — 70 %

       

Environmental friendly

RoHS

No excessive harmful substances

No excessive harmful substances

No hazardous substances above threshold values

No hazardous substances above threshold values

       

Standards and Specifications

Connections are standard

IEC 60947-7-1

IEC 60947-7-1

IEC 60947-7-1

IEC 60947-7-1


  • Previous:
  • Next:

  •